Non-cement, Non-hardening Acrylic Waterproof Coating + Self-adhesive Membrane Installation Method, One-day Adhesion, Long-term Reliability!

Publish Date: 2024-04-10 3Views
After long-term exposure to air, it does not harden or dissolve in water, exhibits extremely high adhesion strength, and is suitable for complex construction surfaces. It can automatically detect and repair damaged waterproof layers at leak points. Combined with self-adhesive membrane, one-day bonding, long-term durability! Non-cement, non-hardening acrylic waterproof coating + self-adhesive membrane installation method

After long-term exposure to air,

it does not harden, nor dissolves in water,

high adhesion strength, suitable for complex construction surfaces,

and can automatically locate and repair damaged waterproof layers at leak points.

Combined with self-adhesive waterproof membrane,

one-day bonding, long-term reliability!

Today, let's take a look,

Non-cement, non-hardening acrylic waterproof coating + self-adhesive membrane, installation method!


What is non-cement, non-hardening?


New product — JX370 Non-cement, Non-hardening Acrylic Waterproof Coating, made from acrylics, tree resins, and various additives as a 'non-cement-based' waterproof coating. The product contains no cement, with stable and reliable performance, representing a new generation of environmentally friendly waterproof material. Long-term waterproofing, free of solvents, fully meeting national safety and environmental protection requirements.


Features of non-cement, non-hardening

图片


  • Unique red-colored high-molecular tree resin, environmentally friendly without cement;

  • Excellent flexibility and elongation, strong substrate adaptability;

  • Outstanding chemical resistance, aging resistance, and self-healing capability;

  • Forms a 'skin-like' bond with the membrane, enhancing overall integrity and allowing higher design standards for waterproofing;

  • Excellent heat and low-temperature resistance, super strong adhesion strength;

  • Good workability.



Non-cement, non-hardening acrylic waterproof coating + self-adhesive membrane,

Installation method,

Process flow,

Base inspection — Base cleaning — Applying base treatment compound — Spot application of non-cement, non-hardening acrylic waterproof coating, Reinforcement layer, (One coat, three applications) — Apply (brush or roll) non-cement, non-hardening acrylic waterproof coating on joints — Simultaneous installation of JX103 non-cement high-molecular fiber-based self-adhesive waterproof membrane — Membrane body lamination — Sealing the edge — On-site self-inspection — Quality inspection — Product protection,


Installation method,
1,
Base cleaning:

The base surface should be solid, flat, dry, clean, and free of oil stains or contaminants.


2,
Coating application: Base treatment compound, :

Apply the base treatment compound evenly on a qualified base surface. Before coating, ensure the compound is thoroughly mixed. During application, apply evenly, avoiding sagging or pooling. Follow the principle of high before low, vertical before horizontal. When the base treatment compound dries, proceed with laying the self-adhesive membrane immediately.


3,
Joint reinforcement treatment:

Pre-treat corners, transitions between horizontal and vertical surfaces, etc., by applying coating first. The thickness should be about 2mm. Then shape the membrane to match the contour and lay it accordingly. After completing the reinforcement layer, proceed with full-surface installation, ensuring consistent thickness across the entire waterproof layer.


4,
Application of non-cement, non-hardening acrylic waterproof coating:

Before application, preheat the coating. Wait until the entire coating reaches a spreadable state (160°C), then apply the non-cement, non-hardening acrylic waterproof coating evenly using brushing or rolling methods on the base surface. Immediately after brushing, lay the non-cement high-molecular fiber-based self-adhesive waterproof membrane.


5,
Laying non-cement high-molecular fiber-based self-adhesive waterproof membrane :

Remove the protective film from the underside of the self-adhesive membrane. Lay the membrane onto the applied waterproof coating, then lightly brush the surface of the membrane to expel internal air, ensuring the membrane adheres firmly to the coating. waterproof coating, forming a seamless bond together. waterproof coating, forming a seamless bond together. Together.


6,
Long and short edge lap bonding:

During lapping, non-cement high-molecular fiber-based self-adhesive waterproof membrane the lap width should not be less than 80mm (different types of membranes follow their respective installation specifications). After lapping, use a roller to press down firmly to ensure bonding strength.


7,
Sealing edges and finishing:

Seal the membrane edges with metal clamps and steel nails, then apply sealant. Proceed with post-installation self-inspection — quality inspection — product protection work.


Important notes,
1,
Before construction, preheat and mix the coating evenly. Recommended brushing temperature: 130–140°C; rolling temperature: 160–170°C. Heating temperature must strictly not exceed 180°C, otherwise it will affect the material’s performance;
2,
The installation process of non-cement, non-hardening acrylic coating involves heating, rolling, etc., large machinery and electrical operations, must be carried out under professional on-site guidance by trained personnel; 3,
When installing on walls, ensure the membrane does not sag. After waterproofing is completed, apply fixation, wall protection, and other measures;
4,
Non-hardening coatings are compatible with TPO, EPDM series, and other high-molecular membranes (except EPDM), but incompatible with cement-based membranes. Non-hardening coatings cannot be used for lapping installations. Membranes must be installed as a complete unit;
5, Installation environment temperature: 0–35°C. Do not install during rain, snow, or wind above level 5; 6,
On-site safety measures must include electrical, fire, and thermal protection. Workers must wear protective gear and have emergency supplies or medications ready.
施工环境温度为0-35°C,雨、雪天及五级大风天气不得施工;
6
施工现场应做好防电、防火、防烫伤等工作,施工人员应配备劳保用品并备好相应器材或药品。

Latest News

Official Account

Chengdu:Huaqiao City, Jinniu District, Chengdu, Sichuan Province•Creative CenterABuilding 21, Floor 21   Manufacturing Base:No. 56 Xingye 7th Road, Industrial Economic Development Zone, Dayi County, Chengdu, Sichuan Province

Chongqing:Fujia No. 176, Haier Road, Jiangbei District, Chongqing68号   Manufacturing Base:No. 289 Qingsong Road, Tianjia Industrial Park, Tongnan District, Chongqing

National Consultation Hotline

028-87341118或15228990208

After-sales Service

400-0789-166

Copyright@ 2023 Sichuan Jinxing Waterproof Technology Group Co., Ltd. ShuICPBeian No. 2023005631-1

Baidu Baijiahao

Official Douyin

Mini Program Entry

15228990208